Install and go back¶
Get an image¶
The firmware image is a single file named like PolyendTrackerOTv300.ptf (for version
3.0.0). Three ways to get one:
- Releases: tagged versions are published on the fork's
Releases page, with
Modules.zip(the card modules, below) andMidiPresets.zip. - CI builds: every push to
mainbuilds an image. Open the latest CI run onmainand download thefirmware-…artifact (you need to be logged in to GitHub). - Build it yourself: see Building.
Keep the file name
The Tracker's update bootloader only accepts names of exactly 24 characters. Don't
rename the .ptf file.
Install¶
- Copy the
.ptffile to the/Firmwarefolder on the Tracker's SD card (or use USB Storage mode to copy it without taking the card out). - On the Tracker, go to Config > Firmware update, select the file and confirm.
- If the screen stays dark after the update, press the power button once.
Install the modules¶
The synths and the master effects aren't in the firmware image: they
are card modules, .otm files the Tracker loads from the SD card. That includes the five
Mini synths (ACD, FAT, VAP, WTFM, PERC). The only synth built in is Off: no sound and
no settings. A new project's three synth slots start on Off, so nothing loads from the card
until you pick a synth in a slot's Model list (Off is at the top of it).
- Download
Modules.zipfrom the same release as the firmware. - Unzip it. It holds two folders:
Modules, with the.otmfiles, andHelp, with the help texts of Edit Patch and of Config. - Copy both folders to the top of the SD card, so the files sit in
/Modules/(for example/Modules/dx7.otm) and/Help/. If the folders are already there, replace all of their files. - Restart the Tracker.
What's in it:
| Kind | Modules |
|---|---|
| Synths | acd (ACD), fat (FAT), vap (VAP), wtfm (WTFM), perc (PERC), dx7 (DX7), fm4 (FM4), ju6 (JU6), dtype (D-Type), cstype (CS-Type), atype (A-Type), ttype (T-Type drums), eight (8-Type), hand (Hand-Type), btype (B-Type), arc (Arc-Type) |
| Effects | dirt, lofi, chorus, bbd, echo, tape |
- The card synths show in a synth slot's Model list, and the effects in the FX bank. A module only takes memory while a project uses it; Config > Memory shows what is loaded.
- You can leave out modules you don't want: delete their files from
/Modules/. - Update the modules with every firmware update. Modules from another firmware version don't load: the boot screen says the module "needs updating".
- In USB Storage mode you can copy synth modules without
a restart: leaving USB Storage mode reads
/Modules/again. A changed effect module needs a restart. - Without the folder the Tracker plays samples and MIDI as before, with no synths and no master effects. A project that uses a missing synth opens with "Synth N (name) not available" on that slot.
- A synth only loads for a slot the project uses: a pattern plays it, or you pick it as the instrument or give it a model. An older project whose slots were left on WTFM / ACD / VAP but never played loads none of them. A stock or Tracker Mini project that plays ACD, FAT, VAP, WTFM or PERC loads them from the card; if they don't all fit in the card memory, a slot that doesn't fit says so, and Config > Memory shows why.
Go back to stock firmware¶
Keep Polyend's stock image, PolyendTracker_1.9.2.ptf, in /Firmware too. Then either:
- install it the same way, from Config > Firmware update, or
- if OpenTracker doesn't start: put the stock file's name in a text file
/Firmware/ot_restore.txtand power-cycle the Tracker. This check runs before anything else in OpenTracker, so it works even when the rest of the firmware doesn't.
Keep /Firmware tidy
The rear reset button installs a random .ptf from /Firmware. Keep only the
image you want plus the stock one there.
Projects¶
- Projects are saved in the Tracker Mini 2.2.1 format (16-track patterns, three synth slots). Older original-Tracker projects open as they are, with tracks 13–16 empty.
- The fork's additions (Performance scenes, song counts and scenes, MIDI LFOs) are stored
in extra files next to
project.mt. Stock firmware, upstream OpenTracker and the Tracker Mini ignore them and open the project normally. - Stock firmware for the original Tracker reads only tracks 1–8 of 2.x projects (expected from the stock loader's rules; not yet confirmed on a stock unit).